Datasheet

AD7091R Data Sheet
Rev. 0 | Page 4 of 20
Parameter Test Conditions/Comments Min Typ Max Unit
POWER REQUIREMENTS
V
DD
2.7 5.25 V
V
DRIVE
1.65 5.25 V
I
DD
V
IN
= 0 V
5
V
DD
= 5.25 V 22 60 µA
V
DD
= 3 V 21.6 33 µA
Normal ModeOperational
V
DD
= 5.25 V, f
SAMPLE
= 1 MSPS 388 449 µA
V
DD
= 3 V, f
SAMPLE
= 1 MSPS 349 408 µA
V
DD
= 3 V, f
SAMPLE
= 100 kSPS 55 µA
Power-Down Mode
V
DD
= 5.25 V 0.334 4.4 µA
V
DD
= 5.25 V, T
A
= −40°C to +85°C 0.334 1.4 µA
V
DD
= 3 V 0.264 4.2 µA
V
DD
= 3 V, T
A
= −40°C to +85°C 0.264 1.2 µA
I
DRIVE
V
IN
= 0 V
Normal ModeStatic
6
V
DRIVE
= 5.25 V 32 500 nA
V
DRIVE
= 3 V 28 500 nA
Normal ModeOperational
V
DRIVE
= 5.25 V, f
SAMPLE
= 1 MSPS
42
86
µA
V
DRIVE
= 3 V, f
SAMPLE
= 1 MSPS 17 20 µA
Power-Down Mode
V
DRIVE
= 5.25 V 7 41 nA
V
DRIVE
= 3 V 2 28 nA
Total Power Dissipation (P
DD
+ P
DRIVE
) V
IN
= 0 V
Normal ModeStatic
5
V
DD
= V
DRIVE
= 5.25 V 116 318 µW
V
DD
= V
DRIVE
= 3 V 65 101 µW
Normal ModeOperational
V
DD
= V
DRIVE
= 5.25 V, f
SAMPLE
= 1 MSPS
2.3
2.9
mW
V
DD
= V
DRIVE
= 3 V, f
SAMPLE
= 1 MSPS 1 1.3 mW
Power-Down Mode
V
DD
= V
DRIVE
= 5.25 V 1.8 24 µW
V
DD
= V
DRIVE
= 3 V 0.8 13 µW
1
Dynamic performance is achieved with a burst SCLK. Operating a free running SCLK during acquisition phase degrades dynamic performance.
2
See the Terminology section.
3
For V
DRIVE
< V
DD
+ 0.7 V.
4
Sample tested during initial release to ensure compliance.
5
SCLK is operating in burst mode and
CS
is idling high. With a free running SCLK and
CS
pulled low, the I
DD
static current is increased by 30 µA typical at V
DD
= 5.25 V.
6
SCLK is operating in burst mode and
CS
is idling high. With a free running SCLK and
CS
pulled low, the I
DRIVE
static current is increased by 32 µA typical at V
DRIVE
= 5.25 V.