Datasheet
AD650 Data Sheet
Rev. E | Page 4 of 20
AD650J/AD650A AD650K/AD650B AD650S
Model Min Typ Max Min Typ Max Min Typ Max Units
AMPLIFIER OUTPUT (F/V CONVERSION)
Voltage Range
(1500 Ω Min Load Resistance)
0 10 0 10 0 10 V
Source Current
(750 Ω Max Load Resistance) 10 10 10 mA
Capacitive Load
(Without Oscillation)
100 100 100 pF
POWER SUPPLY
Voltage, Rated Performance ±9 ±18 ±9 ±18 ±9 ±18 V
Quiescent Current 8 8 8 mA
TEMPERATURE RANGE
Rated Performance
N Package 0 +70 0 +70 °C
D Package −25 +85 −25 +85 −55 +125 °C
1
Nonlinearity is defined as deviation from a straight line from zero to full scale, expressed as a fraction of full scale.
2
Full-scale calibration error adjustable to zero.
3
Measured at full-scale output frequency of 100 kHz.
4
Refer to F/V conversion section of the text.
5
Referred to digital ground.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min
and max specifications are guaranteed, although only those shown in boldface are tested on all production units.