Datasheet

AD586
Rev. G | Page 4 of 16
AD586M, AD586S, AD586T
@ T
A
= 25°C, V
IN
= 15 V, unless otherwise noted. Specifications in boldface are tested on all production units at final electrical test. Results
from those tests are used to calculate outgoing quality levels. All minimum and maximum specifications are guaranteed, although only
those shown in boldface are tested on all production units, unless otherwise specified.
Table 2.
AD586M AD586S AD586T
Parameter Min Typ Max Min Typ Max Min Typ Max Unit
OUTPUT VOLTAGE 4.998 5.002 4.990 5.010 4.9975 5.0025 V
OUTPUT VOLTAGE
DRIFT
1
0°C to 70°C 2 ppm/°C
−55°C to +125°C 20 10 ppm/°C
GAIN ADJUSTMENT
+6
+6
+6
%
−2 −2 −2 %
LINE REGULATION
1
10.8 V < +V
IN
< 36 V
T
MIN
to T
MAX
±100
µV/V
11.4 V < +V
IN
< 36 V
T
MIN
to T
MAX
±150
±150
µV/V
LOAD REGULATION
1
Sourcing 0 mA < I
OUT
< 10 mA
25°C
100
150
150
µV/mA
T
MIN
to T
MAX
100
150
150
µV/mA
Sinking −10 mA < I
OUT
< 0 mA
25°C
400 400 400 µV/mA
QUIESCENT CURRENT 2
3
2
3
2
3
mA
POWER CONSUMPTION 30 30 30 mW
OUTPUT NOISE
0.1 Hz to 10 Hz 4 4 4 µV p-p
Spectral Density,
100 Hz
100 100 100 nV/√Hz
LONG-TERM STABILITY 15 15 15 ppm/1000 hr
SHORT-CIRCUIT
CURRENT-TO-GROUND
45
60
45
60
45
60
mA
TEMPERATURE RANGE
Specified Performance
2
0 70 −55 +125 −55 +125 °C
Operating Performance
3
−40 +85 −55 +125 −55 +125 °C
1
Maximum output voltage drift is guaranteed for all packages and grades. CERDIP packaged parts are also 100°C production tested.
2
Lower row shows specified performance for A and B grades.
3
The operating temperature range is defined as the temperature extremes at which the device will still function. Parts may deviate from their specified performance
outside their specified temperature range.