Datasheet
AD581–SPECIFICATIONS
Model AD581J AD581K AD581L
Min Typ Max Min Typ Max Min Typ Max Units
OUTPUT VOLTAGE TOLERANCE
(Error from Nominal 10,000 V Output) ⴞ30 ⴞ10 ⴞ5 mV
OUTPUT VOLTAGE CHANGE
Maximum Deviation from +25°C ⴞ13.5 ⴞ6.75 ⴞ2.25 mV
Value, T
MIN
to T
MAX
(Temperature Coefficient) 30 15 5 ppm/°C
LINE REGULATION
15 V ≤ V
IN
≤ 30 V 3.0 3.0 3.0 mV
(0.002) (0.002) (0.002) %/V
13 V ≤ V
IN
≤ 15 V 1.0 1.0 1.0 mV
(0.005) (0.005) (0.005) %/V
LOAD REGULATION
0 ≤ I
OUT
≤ 5 mA 200 500 200 500 200 500 µV/mA
QUIESCENT CURRENT 0.75 1.0 0.75 1.0 0.75 1.0 mA
TURN-ON SETTLING TIME TO 0.1%
1
200 200 200 µs
NOISE (0.1 Hz to 10 Hz) 40 40 40 µV (p-p)
LONG-TERM STABILITY 25 25 25 ppm/1000 hrs.
SHORT-CIRCUIT CURRENT 30 30 30 mA
OUTPUT CURRENT
Source @ +25°C 101010 mA
Source T
MIN
to T
MAX
555 mA
Sink T
MIN
to T
MAX
555 µA
Sink –55°C to +85°C––– mA
TEMPERATURE RANGE
Specified 0 +70 0 +70 0 +70 °C
Operating –65 +150 –65 +150 –65 +150 °C
PACKAGE OPTION
2
TO-5 (H-03B) AD581JH AD581KH AD581LH
Model AD581S AD581T AD581U
Min Typ Max Min Typ Max Min Typ Max Units
OUTPUT VOLTAGE TOLERANCE
(Error from Nominal 10,000 V Output) ⴞ30 ⴞ10 ⴞ5 mV
OUTPUT VOLTAGE CHANGE
Maximum Deviation from +25°C ⴞ30 ⴞ15 ⴞ10 mV
Value, T
MIN
to T
MAX
(Temperature Coefficient) 30 15 10 ppm/°C
LINE REGULATION
15 V ≤ V
IN
≤ 30 V 3.0 3.0 3.0 mV
(0.002) (0.002) (0.002) %/V
13 V ≤ V
IN
≤ 15 V 1.0 1.0 1.0 mV
(0.005) (0.005) (0.005) %/V
LOAD REGULATION
0 ≤ I
OUT
≤ 5 mA 200 500 200 500 200 500 µV/mA
QUIESCENT CURRENT 0.75 1.0 0.75 1.0 0.75 1.0 mA
TURN-ON SETTLING TIME TO 0.1%
1
200 200 200 µs
NOISE (0.1 Hz to 10 Hz) 40 40 40 µV (p-p)
LONG-TERM STABILITY 25 25 25 ppm/1000 hrs.
SHORT-CIRCUIT CURRENT 30 30 30 mA
OUTPUT CURRENT
Source @ +25°C 101010 mA
Source T
MIN
to T
MAX
555 mA
Sink T
MIN
to T
MAX
200 200 200 µA
Sink –55°C to +85°C555 mA
TEMPERATURE RANGE
Specified –55 +125 –55 +125 –55 +125 °C
Operating –65 +150 –65 +150 –65 +150 °C
PACKAGE OPTION
2
TO-5 (H-03B) AD581SH AD581TH AD581UH
NOTES
1
See Figure 7.
2
H = Hermetic Metal Can.
Specifications subject to change without notice.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels.
All min and max specifications are
guaranteed, although only those shown in boldface are tested on all production units.
(@ V
IN
= +15 V and +25ⴗC)
REV. B
–2–