Datasheet

AD5724/AD5734/AD5754
Rev. D | Page 8 of 32
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted.
Transient currents of up to 100 mA do not cause SCR latch-up.
Table 4. Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Parameter Rating
AV
DD
to GND −0.3 V to +17 V
AV
SS
to GND +0.3 V to −17 V
DV
CC
to GND −0.3 V to +7 V
Digital Inputs to GND
−0.3 V to DV
CC
+ 0.3 V or 7 V
(whichever is less)
Digital Outputs to GND
−0.3 V to DV
CC
+ 0.3 V or 7 V
(whichever is less)
REFIN to GND −0.3 V to +5 V
V
OUT
A, V
OUT
B, V
OUT
C, V
OUT
D to GND AV
SS
to AV
DD
DAC_GND to GND 0.3 V to +0.3 V
SIG_GND to GND −0.3 V to +0.3 V
Operating Temperature Range, T
A
Industrial −40°C to +85°C
Storage Temperature Range −65°C to +150°C
Junction Temperature, T
J
max 150°C
24-Lead TSSOP Package
θ
JA
Thermal Impedance 42°C/W
θ
JC
Thermal Impedance 9°C/W
Power Dissipation (T
J
max − T
A
)/ θ
JA
Lead Temperature JEDEC industry standard
Soldering J-STD-020
ESD (Human Body Model) 3.5 kV
ESD CAUTION