Readback Operation
Readback mode is activated by selecting the correct device address
(A2, A1, A0) and then setting the R/
W
bit to 1. By default, the
SDO pin is disabled. After having addressed the AD5751 for a
read operation, setting R/
W
to 1 enables the SDO pin and SDO
data is clocked out on the 5
th
rising edge of SCLK. After the data
has been clocked out on SDO, a rising edge on
SYNC
disables
(tristate) the SDO pin again. Status register data (see
Table 9)
and control register data are both available during the same
read cycle.
The status bits comprise four read-only bits. They are used to
notify the user of specific fault conditions that occur, such as an
open circuit or short circuit on the output, overtemperature
error, or an interface error. If any of these fault conditions occur,
a hardware FAULT is also asserted low, which can be used as a
hardware interrupt to the controller.
See the Detailed Description of Features section for a full
explanation of fault conditions.
HARDWARE CONTROL
Hardware control is enabled by connecting the HW SELECT
pin to DVCC. In this mode, the R3, R2, R1, and R0 pins, in
conjunction with the RSET pin, are used to configure the
output range, as per Table 8.
In hardware mode, there is no status register. The fault condi-
tions (open circuit, short circuit, and overtemperature) are
available on Pin IFAULT, Pin VFAULT, and Pin TEMP. If any
one of these fault conditions is set, a low is asserted on the
specific fault pin. IFAULT, VFAULT, and TEMP are open-drain
outputs and, therefore, can be connected together to allow the
user to generate one interrupt to the system controller to
communicate a fault. If hardwired in this way, it is not possible
to isolate which fault occurred in the system.
TRANSFER FUNCTION
The AD5751 consists of an internal signal conditioning block
that maps the analog input voltage to a programmed output
range. The available analog input range is 0 V to 4.096 V.
For all ranges, both current and voltage, the AD5751 imple-
ments a straight linear mapping function, where 0 V maps to
the lower end of the selected range and 4.096 V maps to the
upper end of the selected range.
Table 9. Input Shift Register Contents for a Read OperationStatus Register
MSB LSB
D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0
A2 A1 A0 1 0 R3 R2 R1 R0 CLRSEL OUTEN RSET PEC error OVER TEMP IOUT fault VOUT fault
Table 10. Status Bit Options
Bit Description
PEC Error This bit is set if there is an interface error detected by CRC-8 error checking. See the Detailed Description of Features section.
OVER TEMP This bit is set if the AD5751 core temperature exceeds approximately 150°C.
IOUT Fault
This bit is set if there is an open circuit on the IOUT pin.
VOUT Fault This bit is set if there is a short circuit on the VOUT pin.