Datasheet

AD5724/AD5734/AD5754 Data Sheet
Rev. F | Page 8 of 31
ABSOLUTE MAXIMUM RATINGS
T
A
= 25°C, unless otherwise noted. Transient currents of up to
100 mA do not cause SCR latch-up.
Table 4.
Parameter Rating
AV
DD
to GND −0.3 V to +17 V
AV
SS
to GND +0.3 V to −17 V
DV
CC
to GND 0.3 V to +7 V
Digital Inputs to GND −0.3 V to DV
CC
+ 0.3 V or 7 V
(whichever is less)
Digital Outputs to GND
−0.3 V to DV
CC
+ 0.3 V or 7 V
(whichever is less)
REFIN to GND −0.3 V to +5 V
V
OUT
A, V
OUT
B, V
OUT
C, V
OUT
D to GND AV
SS
to AV
DD
DAC_GND to GND −0.3 V to +0.3 V
SIG_GND to GND −0.3 V to +0.3 V
Operating Temperature Range, T
A
Industrial −40°C to +85°C
Storage Temperature Range −65°C to +150°C
Junction Temperature, T
J
max 150°C
24-Lead TSSOP Package
θ
JA
Thermal Impedance 42°C/W
θ
JC
Thermal Impedance 9°C/W
Power Dissipation (T
J
max − T
A
)/ θ
JA
Lead Temperature JEDEC industry standard
Soldering J-STD-020
ESD (Human Body Model) 3.5 kV
Stresses at or above those listed under Absolute Maximum
Ratings may cause permanent damage to the product. This is a
stress rating only; functional operation of the product at these
or any other conditions above those indicated in the operational
section of this specification is not implied. Operation beyond
the maximum operating conditions for extended periods may
affect product reliability.
ESD CAUTION