Datasheet
AD5696R/AD5695R/AD5694R Data Sheet
Rev. B | Page 4 of 32
A Grade
1
B Grade
1
Parameter Min Typ Max Min Typ Max Unit Test Conditions/Comments
REFERENCE OUTPUT
Output Voltage
7
2.4975 2.5025 2.4975 2.5025 V At ambient
Reference TC
8, 9
5 20 2 5 ppm/°C
See the
Terminology section
Output Impedance
3
0.04 0.04 Ω
Output Voltage Noise
3
12 12
µV p-p
0.1 Hz to 10 Hz
Output Voltage Noise
Density
3
240 240 nV/√Hz
At ambient; f = 10 kHz, C
L
= 10 nF
Load Regulation Sourcing
3
20
20
µV/mA
At ambient
Load Regulation Sinking
3
40
40
µV/mA
At ambient
Output Current Load
Capability
3
±5
±5
mA V
DD
≥ 3 V
Line Regulation
3
100 100 µV/V At ambient
Long-Term Stability/Drift
3
12 12 ppm After 1000 hours at 125°C
Thermal Hysteresis
3
125 125 ppm First cycle
25 25 ppm Additional cycles
LOGIC INPUTS
3
Input Current ±2 ±2 µA Per pin
V
INL
, Input Low Voltage 0.3 × V
LOGIC
0.3 × V
LOGIC
V
V
INH
, Input High Voltage 0.7 × V
LOGIC
0.7 × V
LOGIC
V
Pin Capacitance 2 2 pF
LOGIC OUTPUTS (SDA)
3
Output Low Voltage, V
OL
0.4 0.4 V I
SINK
= 3 mA
Floating State Output
Capacitance
4 4 pF
POWER REQUIREMENTS
V
LOGIC
1.8 5.5 1.8 5.5 V
I
LOGIC
3 3
µA
V
DD
2.7 5.5 2.7 5.5 V Gain = 1
V
DD
V
REF
+ 1.5 5.5 V
REF
+ 1.5 5.5 V Gain = 2
I
DD
V
IH
= V
DD
, V
IL
= GND, V
DD
= 2.7 V to 5.5 V
Normal Mode
10
0.59 0.7 0.59 0.7 mA Internal reference off
1.1 1.3 1.1 1.3 mA Internal reference on, at full scale
All Power-Down
Modes
11
1 4 1 4 µA −40°C to +85°C
6 6 µA −40°C to +105°C
1
Temperature range: A and B grade: −40°C to +105°C.
2
DC specifications tested with the outputs unloaded, unless otherwise noted. Upper dead band = 10 mV and exists only when V
REF
= V
DD
with gain = 1 or when V
REF
/2 =
V
DD
with gain = 2. Linearity calculated using a reduced code range of 256 to 65,280 (AD5696R), 64 to 16,320 (AD5695R), and 12 to 4080 (AD5694R).
3
Guaranteed by design and characterization; not production tested.
4
Channel A and Channel B can have a combined output current of up to 30 mA. Similarly, Channel C and Channel D can have a combined output current of up to
30 mA up to a junction temperature of 110°C.
5
V
DD
= 5 V. The device includes current limiting that is intended to protect the device during temporary overload conditions. Junction temperature can be exceeded
during current limit. Operation above the specified maximum operation junction temperature may impair device reliability.
6
When drawing a load current at either rail, the output voltage headroom with respect to that rail is limited by the 25 Ω typical channel resistance of the output
devices. For example, when sinking 1 mA, the minimum output voltage = 25 Ω × 1 mA = 25 mV (see Figure 31).
7
Initial accuracy presolder reflow is ±750 µV; output voltage includes the effects of preconditioning drift. See the Internal Reference Setup section.
8
Reference is trimmed and tested at two temperatures and is characterized from −40°C to +105°C.
9
Reference temperature coefficient calculated as per the box method. See the Terminology section for further information.
10
Interface inactive. All DACs active. DAC outputs unloaded.
11