POWER-DOWN OPERATION
The AD5696R/AD5695R/AD5694R contain three separate
power-down modes. Command 0100 is designated for the power-
down function (see Table 7). These power-down modes are
software-programmable by setting eight bits, Bit DB7 to Bit DB0,
in the shift register. There are two bits associated with each DAC
channel. Table 10 shows how the state of the two bits corresponds
to the mode of operation of the device.
Table 10. Modes of Operation
Operating Mode PDx1 PDx0
Normal Operation 0 0
Power-Down Modes
1 kto GND 0 1
100 kto GND 1 0
Three-State 1 1
Any or all DACs (DAC A to DAC D) can be powered down
to the selected mode by setting the corresponding bits. See
Table 11 for the contents of the input shift register during
the power-down/power-up operation.
When both Bit PDx1 and Bit PDx0 (where x is the channel
selected) in the input shift register are set to 0, the parts work
normally with its normal power consumption of 4 mA at 5 V.
However, for the three power-down modes, the supply current
falls to 4 μA at 5 V. Not only does the supply current fall, but the
output stage is also internally switched from the output of the
amplifier to a resistor network of known values. This has the
advantage that the output impedance of the part is known while
the part is in power-down mode. There are three different
power-down options. The output is connected internally to
GND through either a 1 kΩ or a 100 kΩ resistor, or it is left
open-circuited (three-state). The output stage is illustrated in
Figure 53.
Figure 53. Output Stage During Power-Down
The bias generator, output amplifier, resistor string, and other
associated linear circuitry are shut down when the power-down
mode is activated. However, the contents of the DAC register
are unaffected when in power-down. The DAC register can be
updated while the device is in power-down mode. The time
required to exit power-down is typically 4.5 µs for V
DD
= 5 V.
To reduce the current consumption further, the on-chip reference
can be powered off. See the Internal Reference Setup section.
Table 11. 24-Bit Input Shift Register Contents of Power-Down/Power-Up Operation
1
DB23 DB22 DB21 DB20 DB19 to DB16
DB15
to
DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1
DB0
(LSB)
0 1 0 0 X X PDD1 PDD0 PDC1 PDC0 PDB1 PDB0 PDA1 PDA0
Command bits (C3 to C0)
Address bits
Don’t care
Power-Down
Select DAC D
Power-Down
Select DAC C
Power-Down
Select DAC B
Power-Down
Select DAC A