Datasheet
AD5570
Rev. C | Page 4 of 24
Parameter
1
Min Typ
2
Max
Unit Test Conditions/Comments
POWER REQUIREMENTS
V
DD
/V
SS
±11.4 ±16.5 V
I
DD
4 5 mA V
OUT
unloaded
I
SS
3.5 5 mA V
OUT
unloaded
Power-Down Current 16 μA V
OUT
unloaded
Power-Supply Sensitivity
6
0.1 LSB/V ±15 supplies ±10%; full-scale loaded
Power Dissipation 100 mW V
OUT
unloaded
1
Temperature ranges: A and B versions = − 40°C to +85°C; W and Y versions = −40°C to +125°C.
2
Typical specifications at ±12 V/±15 V, +25°C.
3
These numbers are generated from the life test of the part.
4
Guaranteed by design.
5
Warmup time is required for the device to reach thermal equilibrium, thus achieving rated performance.
6
Sensitivity of negative full-scale error and positive full-scale error to V
DD
, V
SS
variations.