Datasheet

AD5370
Rev. 0 | Page 23 of 28
SPECIAL FUNCTION MODE
If the mode bits are 00, the special function mode is selected, as shown in Table 12. Bit I21 to Bit I16 of the serial data-word select the special
function, and the remaining bits are data required for execution of the special function, for example, the channel address for data readback.
The codes for the special functions are shown in
Table 13. Table 14 shows the addresses for data readback.
Table 12. Special Function Mode
I23 I22 I21 I20 I19 I18 I17 I16 I15 I14 I13 I12 I11 I10 I9 I8 I7 I6 I5 I4 I3 I2 I1 I0
0 0 S5 S4 S3 S2 S1 S0 F15 F14 F13 F12 F11 F10 F9 F8 F7 F6 F5 F4 F3 F2 F1 F0
Table 13. Special Function Codes
Special Function Code
S5 S4 S3 S2 S1 S0 Data (F15 to F0) Action
0 0 0 0 0 0 0000 0000 0000 0000 NOP.
0 0 0 0 0 1 XXXX XXXX XXXX X [F2:F0] Write to the Control register.
F4 = overtemperature indicator (read-only bit). This bit should be 0 when
writing to the Control register.
F3 = reserved. This bit should be 0 when writing to the Control register.
F2 = 1: select register X1B for input.
F2 = 0: select register X1A for input.
F1 = 1: enable temperature shutdown.
F1 = 0: disable temperature shutdown.
F0 = 1: soft power-down.
F0 = 0: soft power-up.
0 0 0 0 1 0 XX[F13:F0] Write data in F13:F0 to OFS0 register.
0 0 0 0 1 1 XX[F13:F0] Write data in F13:F0 to OFS1 register.
0 0 0 1 0 0 Reserved Reserved.
0 0 0 1 0 1 See Table 14 Select register for readback.
0 0 0 1 1 0 XXXX XXXX [F7:F0]
Write data in F7:F0 to
A/B Select Register 0.
0 0 0 1 1 1 XXXX XXXX [F7:F0]
Write data in F7:F0 to
A/B Select Register 1.
0 0 1 0 0 0 XXXX XXXX [F7:F0]
Write data in F7:F0 to
A/B Select Register 2.
0 0 1 0 0 1 XXXX XXXX [F7:F0]
Write data in F7:F0 to
A/B Select Register 3.
0 0 1 0 1 0 XXXX XXXX [F7:F0]
Write data in F7:F0 to
A/B Select Register 4.
0 0 1 0 1 1 XXXX XXXX [F7:F0]
Block write
A/B select registers.
F7:F0 = 0, write all 0s (all channels use X2A register).
F7:F0 = 1, write all 1s (all channels use X2B register).
0 1 1 1 0 0 Reserved