Datasheet
AD5306/AD5316/AD5326
Rev. F | Page 13 of 24
0
100
200
300
400
500
600
I
DD
(
μ
A)
3.5 4.02.5 3.0 4.5 5.0 5.5
V
DD
(V)
+25
°
C
–40°C
02066-018
+105
°
C
Figure 18. Supply Current vs. Supply Voltage
0
0.1
0.2
0.3
0.4
0.5
I
DD
(
μ
A)
3.5 4.02.5 3.0 4.5 5.0 5.5
V
DD
(V)
+25
°
C
–40
°
C
+105
°
C
02066-019
Figure 19. Power-Down Current vs. Supply Voltage
0
50
100
150
200
250
I
DD
(
μ
A)
300
350
400
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
V
LOGIC
(V)
T
A
= 25°C
V
DD
= 5V
V
DD
= 3V
DECREASING INCREASING
INCREASINGDECREASING
02066-020
Figure 20. Supply Current vs. Logic Input Voltage
for SDA and SCL Voltage Increasing and Decreasing
T
A
= 25°C
V
DD
= 5V
V
REF
= 5V
V
OUT
A
SCL
C
H1
CH1 1V, CH2 5V, TIME BASE = 1μs/DIV
C
H2
02066-021
Figure 21. Half-Scale Settling (1/4 to 3/4 Scale Code Change)
T
A
= 25°C
V
DD
= 5V
V
REF
= 2V
V
OUT
A
V
DD
C
H1
C
H2
CH1 2V, CH2 200mV, TIME BASE = 200μs/DIV
02066-022
Figure 22. Power-On Reset to 0 V
T
A
= 25°C
V
DD
= 5V
V
REF
= 2V
V
OUT
A
PD
C
H1
CH1 500mV, CH2 5V, TIME BASE = 1μs/DIV
C
H2
02066-023
Figure 23. Exiting Power-Down to Midscale