Datasheet
AD5175
Rev. A | Page 18 of 20
50-TP MEMORY WRITE-ACKNOWLEDGE POLLING
After each write operation to the 50-TP registers, an internal
write cycle begins. The I
2
C interface of the device is disabled.
To determine if the internal write cycle is complete and the
I
2
C interface is enabled, interface polling can be executed. I
2
C
interface polling can be conducted by sending a start condition
followed by the slave address and the write bit. If the I
2
C inter-
face responds with an acknowledge (ACK), the write cycle is
complete and the interface is ready to proceed with further
operations. Otherwise, I
2
C interface polling can be repeated
until it completes.
RESET
The AD5175 can be reset through software by executing
Command 4 (see Table 7) or through hardware on the low
pulse of the
RESET
pin. The reset command loads the RDAC
register with the contents of the most recently programmed
50-TP memory location. The RDAC register loads with
midscale if no 50-TP memory location has been previously
programmed. Tie
RESET
to V
DD
if the
RESET
pin is not used.
SHUTDOWN MODE
The AD5175 can be shut down by executing the software
shutdown command, Command 9 (see Table 7), and setting
the LSB to 1. This feature places the RDAC in a zero-power-
consumption state where Terminal A is disconnected from the
wiper terminal. It is possible to execute any command from
Table 7 while the AD5175 is in shutdown mode. The part can
be taken out of shutdown mode by executing Command 9 and
setting the LSB to 0, or by issuing a software or hardware reset.
RDAC ARCHITECTURE
To achieve optimum performance, Analog Devices, Inc., has
patented the RDAC segmentation architecture for all the
digital potentiometers. In particular, the AD5175 employs a
three-stage segmentation approach, as shown in Figure 28.
The AD5175 wiper switch is designed with the transmission
gate CMOS topology.
A
W
10-BIT
ADDRESS
DECODER
R
L
R
L
R
M
R
M
R
W
S
W
R
W
08719-008
Figure 28. Simplified RDAC Circuit
PROGRAMMING THE VARIABLE RESISTOR
Rheostat Operation
The nominal resistance between Terminal W and Terminal A,
R
WA
, is available in 10 kΩ and has 1024-tap points accessed by
the wiper terminal. The 10-bit data in the RDAC latch is decoded
to select one of the 1024 possible wiper settings. As a result, the
general equation for determining the digitally programmed
output resistance between the W terminal and A terminal is
WAWA
R
D
DR ×=
1024
)(
(1)
where:
D is the decimal equivalent of the binary code loaded in the
10-bit RDAC register.
R
WA
is the end-to-end resistance.
In the zero-scale condition, a finite total wiper resistance of
120 Ω is present. Regardless of which setting the part is oper-
ating in, take care to limit the current between the A terminal
to W terminal, and W terminal to B terminal, to the maximum
continuous current of ±6 mA, or the pulse current specified in
Table 3. Otherwise, degradation or possible destruction of the
internal switch contact can occur.