Datasheet

AD5162
Rev. C | Page 10 of 20
–30
–20
–10
0
10
20
POTENTIOMETER MODE TEMPCO (ppm/°C)
30
40
50
1289632 640 160 192 224 256
CODE (DECIMAL)
04108-0-015
R
AB
= 10k
V
DD
= 2.7V
T
A
= –40°C TO +85°C, –40°C TO +125°C
V
DD
= 5.5V
T
A
= –40°C TO +85°C, –40°C TO +125°C
Figure 15. Potentiometer Mode Tempco ΔV
WB
T vs. Code
–60
–54
–48
–42
–36
–30
–24
–18
–12
–6
0
GAIN (dB)
FREQUENCY (Hz)
10k 1M100k 10M
04108-0-016
0x80
0x40
0x20
0x10
0x08
0x04
0x010x02
Figure 16. Gain vs. Frequency vs. Code, R
AB
= 2.5 k
–60
–54
–48
–42
–36
–30
–24
–18
–12
–6
0
GAIN (dB)
FREQUENCY (Hz)
1k 100k10k 1M
04108-0-017
0x80
0x40
0x20
0x10
0x08
0x04
0x01
0x02
Figure 17. Gain vs. Frequency vs. Code, R
AB
= 10 k
–60
–54
–48
–42
–36
–30
–24
–18
–12
–6
0
GAIN (dB)
FREQUENCY (Hz)
1k 100k10k 1M
04108-0-018
0x80
0x40
0x20
0x10
0x08
0x04
0x01
0x02
Figure 18. Gain vs. Frequency vs. Code, R
AB
= 50 k
–60
–54
–48
–42
–36
–30
–24
–18
–12
–6
0
GAIN (dB)
FREQUENCY (Hz)
1k 100k10k 1M
04108-0-019
0x80
0x40
0x20
0x10
0x08
0x04
0x01
0x02
Figure 19. Gain vs. Frequency vs. Code, R
AB
= 100 k
–60
–54
–48
–42
–36
–30
–24
–18
–12
–6
0
GAIN (dB)
FREQUENCY (Hz)
10k1k 100k 1M 10M
04108-0-020
100k
60kHz
50k
120kHz
10k
570kHz
2.5k
2.2MHz
Figure 20. 3 dB Bandwidth at Code = 0x80