Datasheet
REV. A
AD1896
–13–
–130
–131
–132
–133
–134
–135
–136
–137
–138
–139
–140
30 55 80 105 130 155 180
DNR – dBFS
OUTPUT SAMPLE RATE – kHz
TPC 31. DNR vs. Output Sample Rate, f
S_IN
= 96 kHz,
–60 dBFS 1 kHz Tone
0
–20
–40
–60
–80
–100
–120
–140
0 10 20 30 40 50 60
dBFS
FREQUENCY – kHz
192kHz:96kHz
192kHz:48kHz
192kHz:32kHz
TPC 32. Digital Filter Frequency Response
–135
–136
–137
–138
–139
–140
–141
–142
–143
–144
–145
30 55 80 105 130 155 180
DNR – dBFS
OUTPUT SAMPLE RATE – kHz
TPC 33. DNR vs. Output Sample Rate, f
S_IN
= 48 kHz,
–60 dBFS 1 kHz Tone
–135
–136
–137
–138
–139
–140
30 55 80 105 130 155 180
OUTPUT SAMPLE RATE – kHz
DNR – dBFS
TPC 34. DNR vs. Output Sample Rate, f
S_IN
= 44.1 kHz,
–60 dBFS 1 kHz Tone
0.00
–0.01
–0.02
–0.03
–0.04
–0.05
–0.06
–0.07
–0.08
–0.09
–0.10
dBFS
0 2 4 6 8 10 12 14 16 18 20 22 24
FREQUENCY – kHz
192kHz:48kHz
TPC 35. Pass-Band Ripple, 192 kHz:48 kHz
–5
5
–4
–3
–2
–1
0
1
2
3
4
–140 0–120 –100 –80 –60 –40 –20
INPUT LEVEL – dBFS
LINEARITY ERROR – dBr
TPC 36. Linearity Error, 48 kHz:48 kHz, 0 dBFS to
–140 dBFS Input, 200 Hz Tone