ORDERING GUIDE
Max Cal Max Error Max Nonlinearity Package
Model Error @ +25
8
C –25
8
C to +105
8
C –25
8
C to +105
8
C Option
AD592CN 0.5°C 1.0°C 0.35°C TO-92
AD592BN 1.0°C 2.0°C 0.4°C TO-92
AD592AN 2.5°C 3.5°C 0.5°C TO-92
AD592–SPECIFICATIONS
AD592AN AD592BN AD592CN
Model Min Typ Max Min Typ Max Min Typ Max Units
ACCURACY
Calibration Error @ +25°C
1
1.5 2.5 0.7 1.0 0.3 0.5 °C
T
A
= 0°C to +70°C
Error over Temperature 1.8 3.0 0.8 1.5 0.4 0.8 °C
Nonlinearity
2
0.15 0.35 0.1 0.25 0.05 0.15 °C
T
A
= –25°C to +105°C
Error over Temperature
3
2.0 3.5 0.9 2.0 0.5 1.0 °C
Nonlinearity
2
0.25 0.5 0.2 0.4 0.1 0.35 °C
OUTPUT CHARACTERISTICS
Nominal Current Output
@ +25°C (298.2K) 298.2 298.2 298.2 µA
Temperature Coefficient 1 1 1 µA/°C
Repeatability
4
0.1 0.1 0.1 °C
Long Term Stability
5
0.1 0.1 0.1 °C/month
ABSOLUTE MAXIMUM RATINGS
Operating Temperature –25 +105 –25 +105 –25 +105 °C
Package Temperature
6
–45 +125 –45 +125 –45 +125 °C
Forward Voltage (+ to –) 44 44 44 V
Reverse Voltage (– to +) 20 20 20 V
Lead Temperature
(Soldering 10 sec) 300 300 300 °C
POWER SUPPLY
Operating Voltage Range 4 30 4 30 4 30 V
Power Supply Rejection
+4 V < V
S
< +5 V 0.5 0.5 0.5 °C/V
+5 V < V
S
< +15 V 0.2 0.2 0.2 °C/V
+15 V < V
S
< +30 V 0.1 0.1 0.1 °C/V
NOTES
1
An external calibration trim can be used to zero the error @ +25°C.
2
Defined as the maximum deviation from a mathematically best fit line.
3
Parameter tested on all production units at +105°C only. C grade at –25°C also.
4
Maximum deviation between +25°C readings after a temperature cycle between –45°C and +125°C. Errors of this type are noncumulative.
5
Operation @ +125°C, error over time is noncumulative.
6
Although performance is not specified beyond the operating temperature range, temperature excursions within the package temperature range will not damage the device.
Specifications subject to change without notice.
Specifications shown in boldface are tested on all production units at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min
and max specifications are guaranteed, although only those shown in boldface are tested on all production units.
(typical @ T
A
= +258C, V
S
= +5 V, unless otherwise noted)
TEMPERATURE SCALE CONVERSION EQUATIONSMETALIZATION DIAGRAM
66MILS
42MILS
V+
V–
REV. A
–2–
°R = °F +459.7
K = °C +273.15
8C =
5
9
(8F –32)
8F =
9
5