Specifications

SECTION 12 ERROR CODES
66
CLEARING ERROR CODES ON THE SMC40
Program Checksum Failure (EC 124 on single axis
SMC40’s and EC 125 on Dual or Triple SMC40
Controllers)
The very first screen will have a blank screen as shown
to your right. The user will need to type in the
instructions Procedures as written below:
Note: You may or may NOT see the first few
commands. Type in FD=1 so that text can be displayed
(full duplex). The program will then begin showing
instructions on the screen.
Procedure Comment
1. @0 Begins Communication
2. @0 ID Board should return with it’s name and number of axes
3. @0 PA0 Turns off Auto Start Mode
4. @0 PQ Stops all Programs
5. @0 PC RESET Resets the SMC40
6. @0 PC CLEAR Makes sure all programs are cleared out of memory
7. @0 EC0 Clears out the Error Code
8. Board Power Press the Board Reset button. LED should be on Solid
9. @0 Resume Communication. Error is now cleared.
Most Errors can be cleared using the Command EC which clears the Errors.
@0 EC0 <Enter> Enter EC0 and press Enter