Specifications
SECTION 12 ERROR CODES
61
SECTION 12 - error codes (Continued)
113. Internal_MissingControllerBEInstructions
114. Internal_MissingXIndexerBEInstructions
115. Internal_MissingYIndexerBEInstructions
116. Internal_MissingZIndexerBEInstructions
117. Internal_CorruptedControllerProgram
118. Internal_CorruptedXIndexerProgram
119. Internal_CorruptedYIndexerProgram
120. Internal_CorruptedZIndexerProgram
121. Internal_InvalidProgramMemory
122. Internal_ErrorStackOverflow
123. Internal_NVMemoryNotInitialized
124. Internal_NVProgramChecksumFailure
125. Internal_ProgramTerminatorDeletion
BLINKING ERROR CODES (INDEXER)
The SMC40 Indexer will flash an error code (LED on Indexer Side) . Their will be a slow blink followed by a fast
blink when an error occurs. The number of times that flash slow is first and the fast flash is second.
Example: Five Slow (5) flashes and Nine Fast (9) flashes, this would indicate that the SMC40 has Error 59
occurring which means you have an Auto Correction Failure on Axis X..
Example: Nine Slow (9) flashes and One Fast (1) flash, this would indicate that the SMC40 has Error 91
occurring. Error Code 91 means you have no thumbwheel module connected but you used a command
in your line code.