Specifications
SECTION 8 COMMAND DESCRIPTIONS
49
ENCODER COMMANDS
ENCODER AUTOCORRECT ( Enable/ Disable)
This Command will set the Encoder Autocorrection Bit. A 1 will cause the Autocorrection feature
to be enabled, and a 0 will cause it to be disabled. If the Autocorrection feature is enabled, after
the completion of a move, the Encoder Register will be verified to see if it is in the correct position.
If it is not, a correction move will be implemented. See Encoder Retries.
Note: Anytime the ER register, EP register, EW register, or the EM register is written to, the
Encoder Auto Correction feature is disabled to prevent spontaneous Motor Errors - hence it
will need to be re-enabled. Make sure to use the Encoder Auto Correction command as the
last encoder line command to avoid disabling.
Line Command Parameter 1 Parameter 2 Comments
Enc Auto 1
ENCODER DELAY
This Command will set the dwell time that the unit will wait before checking the Encoder Register,
after the end of the move. This will take out the ringing that might be associated with the
mechanics of the system. The range for this is between 1 and 1000 and is in 0.001 seconds [1000
is 1 second]. (Encoder Delay is used to allow for the motor settling time after a move.)
Note: Anytime the ER register is written to, the Encoder Stall Detection feature is disabled to
prevent spontaneous Motor Errors - hence it will need to be re-enabled.
Line Command Parameter 1 Parameter 2 Comments
1 Enc Delay 500 ½ second
ENCODER POSITION (EP)
This Command will set the starting point of the Encoder Position.
Note: Anytime the EP register is written to, the Stall Detection and Encoder Auto - Correction
features are disabled to prevent spontaneous Motor Errors - hence they will need to be re -
enabled.
Line Command Parameter 1 Parameter 2 Comments
1 Enc Position 0 Position 0 can be
the Home Position
ENCODER RETRIES (ER)
This Command will set the number of Encoder Retries or number of tries (0 - 250) when
autocorrecting.
Note: Anytime the ER register is written to, the Encoder AutoCorrection feature is disabled to
prevent spontaneous Motor Errors - hence it will need to be re - enabled.
Line Command Parameter 1 Parameter 2 Comments
1 Enc Retries 5 retry 5 times