www.rosemount.com
Rosemount 5300 Series
October 2014
Diagnostic functionality
D01 FOUNDATION fieldbus Diagnostics Suite (includes Signal Quality Metrics diagnostics)
★
DA1 HART Diagnostics Suite (includes Signal Quality Metrics diagnostics)
★
Verification reflectors (high level supervision)
HL1
Verification reflector - 3” to 6” pipe/chamber (High Level Supervision). See page 29 for details.
(31)
(consult factory for details)
HL2
Verification reflector - 8” pipe/chamber (High Level Supervision). See page 29 for details.
(31)
(consult factory for details)
HL3
Verification reflector - tanks and 10” or wider pipe/chamber (High Level Supervision). See page 29 for details.
(31)
(consult factory for details)
Centering discs (see page 54 for size recommendation) Outer diameter
S2 2-in. Centering disc
(32)
1.8 in. (45 mm)
★
S3 3-in. Centering disc
(32)
2.7 in. (68 mm)
★
S4 4-in. Centering disc
(32)
3.6 in. (92 mm)
★
P2 2-in. Centering disc PTFE
(33)
1.8 in. (45 mm)
★
P3 3-in. Centering disc PTFE
(33)
2.7 in. (68 mm)
★
P4 4-in. Centering disc PTFE
(33)
3.6 in. (92 mm)
★
S6 6-in. Centering disc
(32)
5.55 in. (141 mm)
S8 8-in. Centering disc
(32)
7.40 in. (188 mm)
P6 6-in. Centering disc PTFE
(33)
5.55 in. (141 mm)
P8 8-in. Centering disc PTFE
(33)
7.40 in. (188 mm)
Remote housing mounting (see page 76)
B1 1 m / 3.2 ft. Remote Housing Mounting Cable and Bracket
B2 2 m / 6.5 ft. Remote Housing Mounting Cable and Bracket
B3 3 m / 9.8 ft. Remote Housing Mounting Cable and Bracket
Consolidate to chamber (see page 51)
XC Consolidate to Chamber
(34)
Reference reflectors for dynamic vapor compensation probes (required for probe type 3V and 4U)
(See page 37 for reflector length guidelines)
R1 Short reflector. Length=14 in. (350 mm)
R2 Long reflector. Length=20 in. (500 mm)
Engineered solutions (see page 50)
Rxxxx Engineered Solutions beyond standard model codes. (Consult factory for details)
Example model string: 5301-H-A-1-S-1-V-1A-M-002-05-AA-I1-M1C1
E-002-05, means 2 ft and 5 in. probe length. M-002-05, means 2.05 m.
Table 1. 5301 and 5302 Level and/or Interface in Liquids Ordering Information
The starred options (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject