Operating instructions
10  | ni.com |  NI cRIO-9030 Operating Instructions and Specifications
Figure 3. Installing a Ferrite on the Power Leads
3. Loosen the connector screw flanges and remove the power screw terminal connector plug 
from the cRIO controller. Figure 4 shows the terminal screws, which secure the wires in the 
screw terminals, and the connector screw flanges, which secure the connector plug on the 
front panel.
Figure 4. Power Screw Terminal Connector Plug
Caution  Do not tighten or loosen the terminal screws on the power connector while 
the power is on.
4. Connect the positive lead of the primary power source to the V1 terminal of the power 
connector plug and tighten the terminal screw to 0.20 to 0.25 N · m (1.8 to 2.2 lb · in.) of 
torque.
5. Connect the negative lead of the power supply to one of the C terminals of the power 
connector and tighten the terminal screw to 0.20 to 0.25 N · m (1.8 to 2.2 lb · in.) of torque.
6. Optionally, you can connect the positive lead of another power supply to the V2 terminal 
and the negative lead to the other C terminal.
Caution  The C terminals are internally connected to each other, but are not 
connected to chassis ground. This isolation is intended to prevent ground loops and 
does not meet UL ratings for safety isolation. You can connect the C terminals to 
chassis ground externally. Refer to the Power Requirements section for information 
about the power supply input range. Refer to the Safety Voltages section for 
information about the maximum voltage from terminal to chassis ground.
1 Terminal Screw 2 Connector Screw Flanges
C
V2
C
V1
2
1
2