User Guide
Configuring Communication
33
NXP-TPI/4 NetLinx Touch Panel Interface
Configuring Communication
Communication between the TPI/4 and the NetLinx Master consists of using either ETHERNET
(DHCP, Static IP) or ICSNet.
Setting up the TPI/4 Device Number
1. Press the front panel SETUP button to open the Setup page.
2. Press the Protected Setup button (located on the lower-left of the page) to open the Protected Setup
page and display an on-screen keypad.
3. Enter 1988 into the Keypad’s password field and press Done when finished.
4. Press the red Device Number field to open the Device Number keypad (FIG. 21).
5. Enter a Device Number value for the panel into the Device Number Keypad.
The default value is 2275 and the range is from 1 - 32000.
If you are currently using a static IP Address, continue with the IP Settings section -
Configuring a Static IP Address over Ethernet section on page 36.
Before commencing, verify you are using the latest NetLinx Master firmware.
Verify the NetLinx Studio program being used is version 2.x or higher.
FIG. 20 Setup page
Connection Status
Red Connection Status icon -
Green Connection Status icon -
indicates no connection to
indicates active
a Master
communication to a Master
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
When using multiple TPI/4s within a NetLinx System, remember to assign unique
Device Number values to each panel so that all assigned panels appear in the
System listing for the target Master.