NXA-ENET24 Hardware Installation Guide
Installing the Switch
Selecting a Site
Switch units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow
the guidelines below when choosing a location.
The site should:
be at the center of all the devices you want to link and near a power outlet.
be able to maintain its temperature within 0 to 50 °C (32 to 122 °F), and its humidity
within 5% to 95%, non-condensing
provide adequate space (approximately two inches) on all sides for proper air flow
be accessible for installing, cabling, and maintaining the devices
allow the status LEDs to be clearly visible
Make sure that twisted-pair cable is always routed away from power lines, fluorescent lighting
fixtures and other sources of electrical interference, such as radios and transmitters.
Make sure that the unit is connected to a separate grounded power outlet that:
provides 100 to 240 VAC, 50 to 60 Hz
is within 2.44 m (8 feet) of each device
is powered from an independent circuit breaker
As with any equipment, using a filter or surge suppressor is recommended.
Ethernet Cabling
To ensure proper operation when installing the switch into a network, make sure that the current cables
are suitable for 10BASE-T or 100BASE-TX operation. Check the following criteria against the current
installation of your network:
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables with RJ-45
connectors; Category 3 or better for 10BASE-T and Category 5 or better for 100BASE-TX.
Protection from radio frequency interference emissions
Electrical surge suppression
Separation of electrical wires (switch related or other) and electromagnetic fields from data
based network wiring
Safe connections with no damaged cables, connectors or shields
FIG. 11 RJ-45 Connections
RJ-45 Connector