Installing Wall-Mount (MXD) Panels
50
Modero X® Series Touch Panels - Installation & Hardware Reference Manual
NOTE: When installing the panel, do NOT press on or near the center of the panel. Too much stress at the center may damage
the touch screen surface. When installing the panel, pressure should be applied toward the ends of the panel ONLY.
10. Use the six provided screws, three at each end, to secure the touch panel to the Backbox.
Use only the provided screws, as other screws may damage the touch panel.
11. Snap the decorative side covers onto each end of the panel.
12. Reconnect the terminal Ethernet and USB cables to their respective ports.
Power via 13.5V
The MXT-2000XL-PAN and MXT-1900L-PAN use a 13.5V -compliant power supply to provide power to the panel via the 2-pin 3.5
mm captive wire PWR connector. The incoming PWR and GND wires from the power supply must be connected to the corresponding
locations within the PWR connector.
NOTE: Connecting power to the panel should be done using the included 2-pin 3.5mm captive wire connector included with the
device. This connector is retained within its port with locking screws instead of the pins on each side of standard captive wire
connectors, and using force to insert a standard captive wire connector may damage the device.
Wiring a 13.5V Power Connection
To use the 2-pin 3.5 mm captive wire connector with a 13.5V -compliant power supply, the incoming PWR and GND wires from
the external source must be connected to their corresponding locations on the connector (FIG. 34). The connector uses locking
screws to insure a connection to the device, so make sure to insert and tighten the screws before applying power.
1. Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm captive wire cable.
Match the wiring locations of the +/- on both the power supply and the terminal connector.
2. Tighten the clamp to secure the two wires.
Do not tighten the screws excessively; doing so may strip the threads and damage the connector.
3. Verify the connection of the 2-pin 3.5 mm captive wire to the external 13.5V -compliant power supply and apply power.
Uninstalling the MXD-2000XL-PAN / MXT-1900L-PAN
The MXD-2000XL-PAN and MXD-1900L-PAN are secured to the Backbox via screws. In certain circumstances, such as firmware
updates or other maintenance that requires accessing the device’s USB or Micro-USB ports, the panel may need to be removed
from the Backbox.
The side covers must be removed to access the screws that secure the panel to the Backbox.
Removing the Panel From Its Backbox
1. The MXD-2000XL-PAN and MXD-1900L-PAN have removable side covers on the left and right (landscape) or top and bottom
(portrait) (FIG. 35).
Note that FIG. 35 shows the MXD-1900L-PAN, but the illustration applies equally to the MXD-2000XL-PAN. Also note that
FIG. 35 shows a landscape panel but the installation of a portrait panel is essentially the same, other than the vertical
orientation:
2. For each of the two side covers - insert a flat-head screwdriver (or similar tool) into the removal notches, and carefully prey
each side of the side cover free from the molding.
3. Once the side covers have been removed, the screws securing the panel to the Backbox are accessible.
4. Remove the screws on each side to free the panel from the Backbox.
5. Grasp the bottom of the panel (Landscape) or right side (Portrait) and pull gently outward until the side of the panel is free of
the Backbox. Use your other hand to hold stable the front of the panel.
FIG. 34
NetLinx power connector wiring diagram
FIG. 35 MXD-1900L-PAN Side Covers (highlighted in blue)
PWR +
GND -
To the Touch Panel
Power Supply
Removal notch Removal notch
Side Covers
Removal notch
Removal notch