Technical information
System Status Page
69
RMS - Administrator’s Guide
History - Launches the Device Parameter History Page section on page 70.
Modify - Launches the Modify Parameter Page section on page 71.
Delete - Deletes the parameter.
See Also:
Configure Notification Template Page section on page 156 - modify notification templates to fulfill your own
needs.
Parameter Settings (Cont.)
• Status Type The status represents the type of problem a faulted condition represents. Status
Types include:
• Control System Error
• Equipment Usage
• Help Request
• Maintenance
• Modified Appointment
•Network
• New Appointment
• New NetLinx System
• Not Assigned
• Room Communication Error
•Security
• Server Status
• System Communication Error
Example: When "Lamp Hours" changes from an un-faulted (not greater than
1000) to a faulted (greater than 1000), this change represents a "Maintenance
Request" status that requires an AV technician to repair the equipment.
• If the "Device Online" parameter changes from "Online" to "Offline", this change
could represent a "Security" or "Control System Error" status.
• The RMS application will route the status type to the appropriate personnel as
determined by the Notification Configuration settings.
• Alert Template The notification template to use when the parameter's value is outside the normal
operating range.
• Advise when parameter
returns to normal range
The RMS application sends a notification for a parameter when it returns to its
normal operating range.
• Advise Template The notification template to use when the parameter's value returns to the normal
operating range.
• Alert Macro • The Control Function macro that executes when a device parameter exceeds
its configured threshold.
• The Execute Global option allows you to select any defined macro in the
system and when the parameter Alert occurs, the macro executes in every
room that is part of the macro.
• The Execute Room option allows you to select a macro defined for the room
and when the Alert occurs, the macro executes in the room.
• Advise Macro • The Control Function macro that executes when a device parameter returns to
its configured threshold.
• The Execute Global option allows you to select any defined macro in the
system and when the parameter Advise occurs, the macro executes in every
room that is part of the macro.
• The Execute Room option allows you to select a macro defined for the room
and when the Advise occurs, the macro executes in the room.