Technical information
System Status Page
68
RMS - Administrator’s Guide
Device Parameter Page
Parameter information attributed to a device monitored by the RMS application is listed in the Device
Parameter page (FIG. 68).
FIG. 68 Device Parameter Page
Parameter Settings
• Name The name of the parameter being monitored.
• Current Value The value of the parameter
• Threshold Operator The threshold value is the value for which this parameter is considered to indicate
a problem or fault. The comparison operator is used to detect when the value
changes from the un-faulted to the faulted condition.
• The comparison operators "Less Than", "Less Than or Equal To", "Greater
Than", "Greater Than or Equal To", "Equal To", and "Not Equal To" can be used
for string and number parameters.
• The comparison operators "Contains" and "Does Not Contain" are primarily
used for string parameters.
Example: "Lamp Hours" might have a threshold value of 1000 and any value
over this would require maintenance. The comparison operator would then be
"Greater Than".
• When this parameter changes from a value that is not greater than 1000 to a
value that is greater than 1000, the parameter will faulted.
• When the value changes from a value greater than 1000 to a value not greater
than 1000, the fault status is cleared.
• Threshold The threshold value