Installation guide
- 7 -
ABC-02-USB Installation
Plug the ABC-02-USB into the USB storage port of the Moxa PT-7528
series. We suggest attaching the ABC-02-USB to a wall with an M4 screw.
USB Storage Port (Type A Connector) Pinouts
Pin
Description
1
VCC (+5 V)
2
D- (Data-)
3
D+ (Data+)
4
GND (Ground)
The Reset Button
Depress the Reset button for five continuous seconds to load the factory
default settings. Use a pointed object, such as a straightened paper clip or
toothpick, to depress the Reset button. When you do so, the STATE LED
will start to blink about once per second. Continue to depress the STATE
LED until it begins blinking more rapidly; this indicates that the button has
been depressed for five seconds and you can release the Reset button to
load factory default settings.
NOTE
DO NOT power off the switch when loading default settings
LED Indicators
LED
Color
State
Description
STATE
GREEN
On
System has passed self-diagnosis test
on boot-up and is ready to run.
Blinking
• 1 blink every sec:
The switch is being reset
• 1 blink every 2 sec:
The switch is connected to the
ABC-02-USB.
RED
On
The system failed self-diagnosis on
boot-up.
• RAM Test Fail / System Info. Read Fail
/ Switch Initial Fail / PTP PHY Error.
(+
Green MSTR lit on : HW FAIL)
• FW Checksum Fail / Uncompress Fail.
(+ Green Coupler lit on: SW FAIL)