Installation guide
- 10 -
Alarm Contact
One relay output with current carrying capacity of
3 A @ 30 VDC or 3 A @ 240 VAC
Optical Fiber (100BaseFX)
Distance
Multi-mode:
0 to 5 km, 1300 nm (50/125μm, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125μm, 500 MHz*km)
Single-mode:
0 to 40 km, 1310 nm (9/125μm, 3.5 PS/(nm*km))
Min. TX Output
Multi-mode: -20 dBm; Single-mode: -5 dbm
Max. TX Output
Multi-mode: -10 dBm; Single-mode: 0 dbm
RX Sensitivity
Multi-mode: -32 dBm; Single-mode: -34 dbm
Power
Input Voltage WV: 24/48 VDC (18 to 72 V)
HV: 110/220 VDC/VAC (88 to 300 VDC and 85 to 264
VAC)
Input Current
Max. 0.741 A @ 24 VDC
Max. 0.364 A @ 48 VDC
Max. 0.147/0.077 A @ 110/220 VDC
Max. 0.283/0.19 A @ 110/220 VAC
Physical Characteristics
Housing
IP40 protection, metal case
Dimensions
(W x H x D)
440 x 44 x 325 mm (17.32 x 1.73 x 12.76 in)
Weight
4900 g
Installation
19” rack mounting
Standards and Certifications
Safety
UL 508
Power Automation
IEC 61850-3, IEEE 1613
Road Traffic
NEMA TS2
Rail Traffic
EN 50121-4
EMI
FCC Part 15 Subpart B Class A, EN55022 class A
Environmental Limits
Operating Temp.
-40 to 85°C (-40 to 185°F)
Cold start of min. 100 VAC at -40°C
Storage Temp.
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity.
5 to 95% (non-condensing)
Warranty
Warranty Period
5 years
Details
See www.moxa.com/warranty
Rack Mounting Instructions
1. Elevated Operating Ambient: If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
2. Reduced Air Flow: Installation of the equipment in a rack should
be such that the amount of air flow required for safe operation of the
equipment is not compromised.