Instruction manual

Product Information
3
PLB-CF10 CardFrame
Product Information
Voltage Selection Switch
The switch is located on the right side of the rear panel.
Power-Up Procedure
1. Plug the power cord into a properly matching and grounded 115 VAC or 230 VAC outlet.
2. Turn the power On. The power switch is located at the right side of the rear panel.
3. An LED should be illuminated on the front panel. If there is a problem, contact your Landmark
dealer or Landmark/AMX Technical Support.
PHASTHub Ports
There are two RJ-45 PHASTHub ports on the rear panel. These allow you to daisy-chain the
cardframe to other cardframes or hubs to expand the system size and capabilities. Always connect
the OUT port on this device to the IN port on the next PHASTHub device down the chain. Do not
reverse this connection.
PHASTLink Ports
There are 15 PHASTLink ports on the lower part of the rear panel. These are used to connect
PHASTLink devices to the cardframe. If more ports are required, an additional cardframe or hub
box will be necessary. It does not matter which PHASTLink port you use; they are all functionally
identical.
MCU-to-PC Connection
If a PHAST MCU card is installed, a 10Base-T Ethernet port on the MCU card is used to connect
the to an ethernet board in the PC. Refer to the PLC-MCU Master Control Unit Card Reference
Guide for more information on connecting and using the MCU card.
Make sure that the voltage selection switch is set to the correct line voltage
(115 VAC or 230 VAC).
The OUT connector cable must feed into an IN connector on another device.
The IN connector cable must feed into an OUT connector on another device.