Instruction manual
Product Information
2
SP+ Softwire Panels
Front Panel Controls
Softwire Panel pushbuttons can be programmed individually or in any combination as a single
device or as a group. The bargraph LEDs can also be programmed individually or as a group. The
LEDs can be used with any one of the pushbuttons or as an independent display indicator. FIG. 1
illustrates the standard configuration for the SP+ panels. This is the complete pushbutton
arrangement when all 64 pushbuttons and three LED bargraphs are used. By using custom engraved
panels, you can configure the grouping and marking of the pushbuttons to suit your application.
Rear Panel Components
The SP+ rear panels contain the AXlink bus connector, AXlink LED, and the DIP switch that is
used to set the panel's device number. FIG. 2 shows the back panel component configuration.
! AXlink (indicator) A green LED indicates activity of the AXlink bus connected to an
Axcess Control System.
! Device Number Assigned to devices connected to the AXlink bus. Every device on the
bus must have a unique device code. An 8-position DIP switch is used to set the device
number for the AXP-SP+ Softwire Panels.
FIG. 1 SP+ push-button and bargraph display arrangement
FIG. 2 Side and back panel views of the SP+ standard mounting frame
Pushbutton 1
Pushbutton 8
Pushbutton 9
Pushbutton 64
Bargraph 1
Bargraph 2
Bargraph 3
Device
DIP switch
AXlink Status LED
PWR
AXlink
2
1
4
3
2
1