Specifications
NetLinx Programming
44
 NXV-300 Modero Virtual Touch Panel 
"^" Button Commands (Cont.)
^DPF Delete page flips from button if it already exists.
Syntax:
"'^DFP-<vt addr range>,<actions>,<page name>'"
Variable: 
variable text address range = 1 - 4000.
actions = Stan[dardPage] - Flip to standard page
 Prev[iousPage] - Flip to previous page
 Show[Popup] - Show Popup page 
 Hide[Popup] - Hide Popup page
 Togg[lePopup] - Toggle popup state
 ClearG[roup] - Clear popup page group from all pages
 ClearP[age] - Clear all popup pages from a page with the 
 specified page name
 ClearA[ll] - Clear all popup pages from all pages
page name = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'^DPF-409,Prev'"
Deletes the assignment of a button from flipping to a previous page.
^ENA Enable or disable buttons with a set variable text range.
Syntax: 
"'^ENA-<vt addr range>,<command value>'"
Variable: 
variable text address range = 1 - 4000.
command value = (0= disable, 1= enable)
Example:
SEND_COMMAND Panel,"'^ENA-500.504&510.515,0'"
Disables button pushes on buttons with variable text range 500-504 & 510-515.
^FON Set a font to a specific Font ID value for those buttons with a defined address range. Font ID 
numbers are generated by the TPDesign4 programmers report.
Syntax: 
"'^FON-<vt addr range>,<button states range>,<font value>'"
Variable: 
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
font value = Range = 1 - XXX. Refer to theDefault Font Styles and ID Numbers table on page 31.
Example:
SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"
Sets the font size to font ID #4 for the On and Off states of buttons with the variable text range of 500-
504 & 510-515.
Note: The Font ID is generated by TPD4 and is located in TPD4 through the Main menu. Panel > 
Generate Programmer's Report >Text Only Format >Readme.txt.
^GDI Change the bargraph drag increment.
Syntax: 
"'^GDI-<vt addr range>,<bargraph drag increment>'"
Variable: 
variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.
Example:
SEND_COMMAND Panel,"'^GDI-7,128'"
Sets the bargraph with variable text 7 to a drag increment of 128.