"^" Button Commands (Cont.)
^BCT Set the text color to the specified color. Only if the specified text color is not the same as the current 
color.
Note: Color can be assigned by color name (without spaces), number or R,G,B value (RRGGBB or 
RRGGBBAA).
Syntax: 
"'^BCT-<vt addr range>,<button states range>,<color value>'"
Variable: 
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
color value = Refer to theRGB Values for all 88 Basic Colors table on page 29 for more information.
Example:
SEND_COMMAND Panel,"'^BCT-500.504&510,1,12'"
Sets the Off state border color to 12 (Yellow). Colors can be set by Color Numbers, Color name, 
R,G,B,alpha colors (RRGGBBAA) and R, G & B colors values (RRGGBB).
^BDO Determines what order each layer of the button is drawn.
Syntax: 
"'^BDO-<vt addr range>,<button states range>,<1-5><1-5><1-5><1-5><1-5>'"
Variable: 
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
layer assignments = Fill Layer = 1
 Image Layer = 2
 Icon Layer = 3
 Text Layer = 4
 Border Layer = 5
Note: The layer assignments are from bottom to top. The default draw order is 12345.
Example:
SEND_COMMAND Panel,"'^BDO-530,1&2,51432'"
Sets the button’s variable text 530 ON/OFF state draw order (from bottom to top) to 
Border, Fill, Text, Icon, and Image.
Example 2:
SEND_COMMAND Panel,"'^BDO-1,0,12345'"
Sets all states of a button back to its default drawing order.
^BFB Set the feedback type of the button. ONLY works on General-type buttons. 
Syntax: 
"'^BFB-<vt addr range>,<feedback type>'"
Variable: 
variable text address range = 1 - 4000.
feedback type = (None, Channel, Invert, On (Always on), Momentary, and Blink).
Example:
SEND_COMMAND Panel,"'^BFB-500,Momentary'"
Sets the Feedback type of the button to 'Momentary'.
^BIM Set the input mask for the specified address.
Syntax: 
"'^BIM-<vt addr range>,<input mask>'"
Variable: 
variable text address range = 1 - 4000.
input mask = Refer to the for character types. 
Example:
SEND_COMMAND Panel,"'^BIM-500,AAAAAAAAAA'"
Sets the input mask to ten ’A’ characters, that are required, to either a letter or digit