Specifications
Setup Pages and Descriptions
26
NXV-300 Modero Virtual Touch Panel
Panel Statistics - Blinks Tab
The Blinks Tab tracks blinks, which are messages sent by the master once every 5 seconds to all
connected devices. Features on this tab are as follows:
FIG. 22 Panel Statistics Page - Blinks Tab
Panel Statistics Page - Blinks Tab Elements
Connection Status icon: The icon in the upper-right corner of each Setup page shows online/offline state of
the panel to the master.
• Bright red - disconnected
• Bright green - connected. Blinks when a blink message is received to dark green
every 5 seconds for half a second then go back to bright green.
• Bright yellow - panel missed a blink message from the master. It will remain
yellow for 3 missed blink messages and then turn red. It will return to green
when a blink message is received.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx
Master.
Total: • Received - The total Blink messages received by the panel.
• Missed - The total Blink messages missed by the panel.
Last 15 Minutes: • Received - The total Blink messages received by the panel in the last 15
minutes.
• Missed - The total Blink messages missed by the panel in the last 15 minutes.
Clear: Pressing this button clears all fields on this page.
Refresh: Pressing this button refreshes all data in the fields on this page.
Back: Returns to the previous page.