Specifications
Setup Pages and Descriptions
23
NXV-300 Modero Virtual Touch Panel
G4 Web Control Page
The G4 Web Control page (FIG. 19) centers around enabling and disabling both the display and control
of your panel via the Web. An external computer or Netbook running a VNC client such as Bonjour,
installed during the initial communication to the G4 panel, makes this possible.
The NXV-300 supports the open standard Virtual Network Computing (VNC) interface. This device
contains a VNC server that allows it to accept a connection from any other device running a VNC client.
Once a connection is established to that target device, the client can control the device remotely. The
elements of the G4 Web Control Settings page are as follows:
FIG. 19 G4 Web Control Settings page
G4 Web Control Settings Page Elements
Connection Status icon: This visual display of the connection status allows the user to have a current
visual update of the panel’s connection status regardless of what page is
currently active.
• A Lock only appears on the icon if the panel has established a connection
with a currently secured target Master (requiring a username and password).
G4 Web Control Settings: Sets the remote control values for the touch panel and contains:
Enabled • The Enabled button activates the G4 Web Control feature on the panel and
allows an external PC running a VNC client to access the panel after the
remaining fields are configured. This button is always on.
Timeout: Sets the length of time (in minutes) the panel can remain idle (no cursor
movements) before the session is closed and the user is disconnected.
• Minimum value = 0 minutes (panel never times-out)
• Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)
Network Interface Displays the detected method of communication to the web:
• Wired is used when a direct Ethernet connection is being used for
communication to the web. This is the only setting.
Control Name The Control Name is the same name as the Device Name set in the Protected
Setup Pages. The Control Name cannot be changed.
• This Web Control tab displays a G4 icon alongside the link to the Web Control
Name given to this panel (FIG. 19).
Control Password Allows entry of the G4 Authentication session password associated for VNC
web access of this panel.
Control Port Allows entry of the VNC Web Server’s port value.
• Default value is 5900.