Specifications
Setup Pages and Descriptions
22
NXV-300 Modero Virtual Touch Panel
System Settings Page - Master Tab Elements (Cont.)
Mode: Cycles between the different connection modes (URL, Listen, NDP(UDP),
URL(UDP), and Auto):
•Auto - In this mode, enter the System Number and a username/password (if
applicable). This mode is used when both the panel and the NetLinx Master
are on the same Subnet and the Master has its UDP feature enabled.
- The Master IP/URL field is read-only because the panel obtains this
information from the communicating Master.
• URL - In this mode, enter the Master IP/URL, Master Port Number, and
username/password (if used) on the Master.
- The System Number field is read-only.
• Listen - In this mode, add the Modero panel address into the URL List in
NetLinx Studio and set the connection mode to Listen. This mode allows the
Modero touch panel to "listen" for the Master’s communication signals.
- The System Number and Master IP/URL fields are read-only.
• NDP(UDP) - This mode uses UDP instead of TCP to access the device.
- The System Number and Master IP/URL fields are read-only.
• URL(UDP) - This mode uses UDP instead of TCP to access the device.
- The System number field is read-only.
System Number: Allows you to enter a system number. Default value is 0 (zero).
Master IP/URL: Sets the Master IP or URL of the NetLinx Master. This field is only enabled
when selecting either the URL or the URL(UDP) Modes.
Master Port Number: Enters the port number used with the NetLinx Master.
• Default value is 1319.
Username/Password: If the target Master has been previously secured, enter the alphanumeric string
(into each field) assigned to a pre-configured user profile on the Master.
This profile should have the pre-defined level of access/configuration rights.
NDP Name: The Nexus Delivery Protocol name for the device. The NDP name allows use of
a master web interface, NetLinx Studio 2.4 or commands to bind the device with
NetLinx masters.
Save & Reboot: Saves any changes and reboots the device in order to implement those
changes.