Specifications
NXD-700i - Installation
16
NXD-700i & NXT-CA7 7” Modero Touch Panels
7. Insert the NXA-RK7 (with connected NXD unit) into the equipment rack, making sure to align the screw
holes along the sides on the NXA-RK7 with the holes in the equipment rack.
8. Use a grounded Phillips-head screwdriver to secure the NXA-RK7 to the equipment rack using #10-32
screws (included).
9. Place the Faceplate/Trim Ring assembly back onto the main NXD unit. Make sure to align the
Microphone, Light, and PIR Motion sensor locations to their respective openings on the front faceplate/
bezel.
10. Reconnect Ethernet and USB.
Ethernet/RJ-45 Port: Connections and Wiring
FIG. 16 describes the blink activity for the Ethernet 10/100 Base-T RJ-45 connector and cable.
The Ethernet cable is connected to the rear of Table Top and side of the Wall Mount panels.
The following table lists the pinouts, signals, and pairing associated with the Ethernet connector.
FIG. 17 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.
FIG. 16 Ethernet connector (showing communication and connection LEDs)
Ethernet RJ-45 Pinouts and Signals
Pin Signals Connections Pairing Color
1 TX + 1 --------- 1 1 --------- 2 Orange-White
2 TX - 2 --------- 2 Orange
3 RX + 3 --------- 3 3 --------- 6 Green-White
4 PoE power 4 --------- 4 Blue
5 PoE power 5 --------- 5 4 --------- 5 Blue-White
6 RX - 6 --------- 6 Green
7 PoE power 7 --------- 7 7 --------- 8 Brown-White
8 PoE power 8 --------- 8 Brown
FIG. 17
RJ-45 wiring diagram
ETHERNET
A L
A - Activity LED (yellow)
lights when receiving or
transmitting Ethernet
data packets
L - Link LED (green) lights when
the Ethernet cables are connected
and terminated correctly.
12 3 45 6 78
12 3 45 6 78