Specifications
NXA-PDU-1508-8 (110V/220V)
2
NXA-PDU-1508-8 Power Distribution Unit
NXA-PDU-1508-8 Specifications (Cont.)
Front Panel Components:
POWER LEDs
(1-8):
Eight green LEDs illuminate to indicate that the associated Power Outlet (#1 - #8) is in
use.
AXLINK LEDs:
Two red LEDs illuminate to indicate when the associated AxLink Bus Strips (Bank 1 or
Bank 2) on the PDU is in use.
AXLINK STATUS LED:
Green LED illuminates to indicate AxLink communication activity between the PDU and
the NetLinx Master:
• ON - power, no master connection
•OFF - no power
• Blink - powered, communicating with master
RESET pushbutton:
• Press/hold for 3 seconds: Resets the AxLink power line (minimum 0.5 seconds toggle)
• Press/hold for 17 seconds: Resets the PDU (similar to a full power cycle of the unit)
Rear Panel Components:
AXLINK POWER
connectors (8):
A 13.5VDC, 6.5A power supply is provided for AxLink power.
Eight 3.5mm (4-pin) AxLink captive-wire connectors provide power and data for up to
eight AxLink connections.
• AxLink power is switched in two banks of four outputs each.
BANK 1 contains AxLink connectors 1-4
BANK 2 contains AxLink connectors 5-8
• The PDU provides up to 6.5A total across all AxLink outputs.
MASTER connector
3.5mm Phoenix (4-pin) AxLink connector provides connectivity to the NetLinx Master
(always on).
TEMP (RTS) input:
3.5mm Phoenix (2 pin) connector provides connection to a Remote Temperature Sensor
(RTS).
CONFIG DIP Switch:
Eight-position DIP switch sets the AxLink device address.
Power Outlets (8):
• Connector Type: IEC C-13, 12A/10A
• Maximum allowable current on a single high-voltage output:
10A@110VAC / 8A@220VAC
Power Inlet (1):
• Connector Type: IEC C-14, 12A/10A
110-120VAC: 12A Input
220-240VAC: 10A Input
Dimensions (HWD): • 1 3/16" x 17" x 9 11/16" (2.97cm x 43.18cm x 24.54 cm)
•1 RU
Weight: 9 lbs (4.08 kg)
Enclosure: Steel, black powder coated finish
Environmental: • Operating Environment: 0°C - 40°C (32°F - 104°F)
• Storage Environment: -10°C - 60°C (14°F - 140°F)
• Relative Humidity: 5% - 85%, non-condensing
Certifications: • CE
• CB Scheme
•UL
•FCC
•CSA
•C-Tick
Included Accessories: • Power Cord, NEMA 5-15P TO C13, 15A, 14/3, 6’ (64-0673-01)
Note: See Power Cord Requirements below for details.
• ENV-VST-TSO, Temperature Sensor (FG2050-22)
• (2) Removable mounting brackets
• (9) 4-pin, 3.5mm captive-wire connectors (41-5047)
Other AMX Equipment: • ENV-VST-TSF, Flush Mount Temperature Sensor (FG2050-21)
• CC-C13-C14: C13 to C14 Power Cable (FG10-673-01)
• CC-C14-NEMA: C14 to NEMA Power Cable (FG10-673-02)