Specifications
NXA-PDU-1508-8 (110V/220V)
1
NXA-PDU-1508-8 Power Distribution Unit
NXA-PDU-1508-8 (110V/220V)
Overview
The NXA-PDU-1508-8 Power Distribution Unit (FG673-01) provides switching of mains power to each of
eight AC power outlets. The two built-in AxLink bus strips provide connectivity (AxLink data / power) for up
to eight AxLink connections.
Product Specifications
FIG. 1 NXA-PDU-1508-8
NXA-PDU-1508-8 Specifications
Power:
Note: The PDU auto-
senses the voltage of the
supplied power.
• Powered via 110-220 VAC, 50/60Hz mains power on an IEC-320 C-14 connector
• Required voltage = 110 to 220 VAC, 50/60Hz
• Total Combined Current (including AxLink):
10A at 220V-240V
12A at 110V-120V
• Idle current draw: 0.5W max
AC Current:
• 110-120VAC: Input: 15A Regulatory Derated Input Current
(North America)12A @ 110 VAC
10A Max Load Per Outlet @ 110VAC
12A Max Combined Load @ 110VAC
• 220-240VAC: Input: 10A @ 220 VAC
8A Max Load Per Outlet @ 220VAC
10A Max Combined Load @ 220VAC
Overcurrent
Notification:
• 110-120VAC: Single Outlet: 10A
Overall: 12A
• 220-240VAC: Single Outlet: 8A
Overall: 10A
RESET pushbutton
AxLink STATUS LED
AxLink BANK 1
POWER (Output 1-8 Status) LEDs
Status LED
AxLink BANK 2
Status LED
Power Inlet
AXLINK POWER Connectors
MASTER AxLink Connector (to NetLinx Master Controller)
TEMP (RTS) Input Connector
Power Outlets 1-8
CONFIG DIP Switch
top = BANK 1 (1-4)
bottom = BANK 2 (5-8)
12345678