Specifications

Browser-Based Configuration Pages
36
NXA-ENET8POE Gigabit PoE Ethernet Switch
VLAN Port Config
There are three different parameters that can be configured for each port on the NXA-ENET8POE; VLAN ID
(VLAN membership), PVID and Packet Type. Note that the ports within a trunk cannot be configured
individually; configure the trunk instead (trunks are labelled T1 to T4).
FIG. 25 VLANs- VLAN Port Config page
VLANs - VLAN Port Config page
Port/Trunk: The port number of the port or the ID of a trunk. This cannot be changed.
VLAN aware Enabled:
VLAN aware ports will strip the VLAN tag from received frames and insert the
tag in transmitted frames (except PVID). VLAN unaware ports will not strip the
tag from received frames or insert the tag in transmitted frames.
Ingress Filtering Enabled:
When enabled, allows filtering of incoming packets.
Packet Type:
Sets the interface to accept all frame types, or only tagged frames. If the
Packet Type is set to “All,” the port can accept incoming tagged and untagged
packets. Untagged packets will be associated with the VLAN identified by the
PVID. Tagged packets will be dropped unless the port is a member of the
VLAN identified by the VLAN tag in the packet. If the Packet Type is set to
“Tagged Only,” the port will drop untagged packets and will only receive tagged
packets. Tagged packets will be dropped unless the port is a member of the
VLAN identified by the VLAN tag in the packet. (Default: All)
PVID:
The port VLAN ID (PVID) assigned to untagged frames received on the
interface. From the drop-down menu, choose the VLAN ID that will be
assigned to untagged frames received on the port. You cannot remove a port
from VLAN 1 unless its PVID has been changed to something other than 1.
You can only choose “None” for the VLAN ID when the packet type is set to
“Tagged Only.” Outgoing packets are tagged unless the packet’s VLAN ID is
the same as the PVID. When the PVID is set to “None,” all outgoing packets
are tagged. (Default: 1)
Help:
Links directly to web help.