Specifications

Browser-Based Configuration Pages
18
NXA-ENET8POE Gigabit PoE Ethernet Switch
Status - Overview page (Cont.)
Number of Ports: The number of built-in ports in the device.
Hardware Version:
Hardware version of the main board.
Software Version:
The current software version on the device.
Serial Number:
The serial number of the device.
Address Information:
Management VLAN:
ID of a configured VLAN through which you can manage the device. By
default, all ports on the device are members of VLAN 1. However, the
management station can be attached to a port belonging to any VLAN, as long
as that VLAN has been assigned an IP address.
IP Address:
Address of the VLAN to which the management station is attached. (Note that
the management station must always be on VLAN 1. Valid IP addresses
consist of four decimal numbers, 0 to 255, separated by periods.
Subnet Mask:
This mask identifies the host address bits used for routing to specific subnets.
(Default: 255.255.255.0)
Gateway IP Address:
IP address of the gateway router between the switch and management
stations that exist on other network segments. (Default: 0.0.0.0)
MAC Address:
The physical layer address of the device.
Port Information:
Port:
This field indicates the port number.
Type:
This field indicates the port type.
Link Status:
This field indicates if the link is Up or Down.
Speed/Duplex Status:
Shows the current speed and duplex mode.
10hdx: 10 Mbps half duplex.
10fdx: 10 Mbps full duplex.
100hdx: 100 Mbps half duplex.
100fdx: 100 Mbps full duplex.
1000fdx: 1000 Mbps full duplex.
Flow Control Status:
This field indicates whether flow control is enabled or disabled (IEEE 802.3x,
or Back-Pressure).
Auto-negotiation:
This field shows if auto-negotiation is enabled or disabled.
Frame Type:
Either “Tagged” or “All.” “Tagged” means that the port will only receive VLAN-
tagged frames. When set to “All,” the port will also receive untagged frames.
PVID:
The VLAN ID assigned to untagged frames received on the interface.
Outgoing frames are tagged unless the frame’s VLAN ID is the same as the
PVID. When the PVID is set to “None,” all outgoing frames are tagged.
(Default: 1)
Trunk/LACP Information:
Trunk/LACP:
The trunk label. “T1” through “T4” are used as trunk labels.
Type:
All trunks and ports on this device are 10/100/1000Mbps.
Trunk/LACP Status:
Indicates the speed and duplex setting of the trunk.
10hdx: 10 Mbps half duplex.
10fdx: 10 Mbps full duplex.
100hdx: 100 Mbps half duplex.
100fdx: 100 Mbps full duplex.
1000fdx: 1000 Mbps full duplex.
Ports:
The ports that are members of the trunk.
VLAN Information:
VLAN ID:
A number in the range 1 - 4094 which identifies the VLAN.
VLAN Members:
A list of the ports that are members of the VLAN. By default, all ports are