Specifications
WebConsole - System Options
53
NX-Series Controllers - WebConsole & Programming Guide
Selecting a Custom NIST Server
1. In the NIST Servers tab (FIG. 55), use the radio buttons to select one of the NIST Servers in the list.
2. Click Accept to save these settings to the Master.
Adding a Custom NIST Server to the List
1. Click on the radio button next to the last (blank) entry in the NIST Server Manager list.
2. In the URL field, enter the URL of the NIST Server. The URL is used only to help you manage entries, and is not
verified or used internally by the clock manager.
3. Enter the NIST Server’s IP Address in the IP field. This is used internally and must be a valid IP address.
Note: The strings entered into the URL and Location fields are not used to connect to NIST Servers. The IP Address
(entered into the IP field) specifies the NIST Server(s) that will be used. As stated above, the address entered into the IP
field must be must be a valid IP address (not a URL).
4. Enter the NIST Server’s location in the Location field. This is used only to help the user manage entries and it is
not verified or used internally by the clock manager.
5. Click Accept to save these settings to the Master.
Removing an NIST Server From the List
1. Click on the Remove (x) button to the right of a user-added NIST Server in the NIST Server Manager list.
2. Click Accept to save these settings to the Master.
Note: The built-in entries cannot be removed.
Clock Manager NetLinx Programming API
Refer to Appendix C: Clock Manager NetLinx Programming API section on page 145 for a listing and description of the
Types/Constants and Library Calls that are included in the NetLinx.AXI to support Clock Manager functions.
FIG. 55 Clock Manager Options - NIST Servers tab