Specifications

Initial Configuration
5
NI & DVX Central Controllers - WebConsole & Programming Guide
Initial Configuration
Overview
This section describes using the NetLinx Studio software application to perform the initial configuration of the NetLinx
Master. NetLinx Studio is used to setup a System number, obtain/assign the IP/URL for the NI Controller, as described
in this section (as well as to transfer firmware Kit files to the Master - see the Upgrading Firmware section on page 17).
Before You Start
1. Verify you have the latest version of the NetLinx Studio application installed on your PC.
NetLinx Studio is available to download from www.amx.com. Login to download the latest version. Alternatively,
if it is already installed, use the Web Update option in NetLinx Studio’s Help menu to obtain the latest version.
The default location for the NetLinx Studio application is Start > Programs > AMX Control Disc > NetLinx
Studio > NetLinx Studio.
2. Verify that an LAN/ICSNet cable is connected from the NI Controller to the LAN Hub.
3. Connect an programming cable (RS-232) from the Program Port on the Central Controller to a COM port on the
PC being used for programming.
NI-4000/4100 only: Verify that any control cards are inserted and their respective connectors are attached.
4. Verify that the NI Controller is powered on.
Preparing the NI Controller for Serial Communication
To establish serial communication with the NI Controller via the PROGRAM (DB9) port:
1. Launch NetLinx Studio and select Settings > Master Communication Settings (FIG. 2):
2. This opens the Master Communication Settings dialog (FIG. 3).
FIG. 2 NetLinx Studio menu bar - Settings > Master Communication Settings
FIG. 3 Master Communication Settings dialog