Specifications

Terminal (Program Port/Telnet) Commands
105
NI & DVX Central Controllers - WebConsole & Programming Guide
Terminal Commands (Cont.)
Command Description
SET HTTPS PORT Sets the Master’s IP port listened to for HTTPS connections.
Note: The Master must be rebooted to enable new settings.
Example:
>SET HTTPS PORT
Current HTTPS port number = 443
Enter new HTTPS port number (Usually 443) (0=disable HTTPS):
Once you enter a value and press the ENTER key, you get the following message:
Setting HTTPS port number to
New HTTPS port number set, reboot the Master for
the change to take affect.
SET ICSP PORT Sets the Master’s IP port listened to for ICSP connections.
Note: The Master must be rebooted to enable new settings.
Example:
>SET ICSP PORT
Current ICSP port number = 1319
Enter new ICSP port number (Usually 1319)
(0=disable ICSP):
Once you enter a value and press the ENTER key, you get the following message:
Setting ICSP port number to
New ICSP port number set, reboot the Master for the
change to take affect.
SET ICSP TCP TIMEOUT Sets the timeout period for ICSP and i!-Web Control TCP connections.
Note: The new timeout value is immediately (no reboot required).
Example:
>SET ICSP TCP TIMEOUT
This will set the timeout for TCP connections for both ICSP and i!-Web
Control.When no communication has been detected for the specified
number of seconds, the socket connection is closed.ICSP and i!-Web
Control have built-in timeouts and reducing the TCP timeout below
these will cause undesirable results. The default value is 45
seconds.
The current ICSP TCP timeout is 45 seconds
Enter new timeout (in seconds):
Once you enter a value and press the ENTER key, you get the following message:
New timeout value set (in affect immediately).
SET IP <D:P:S> Sets the IP configuration of a specified device.
Enter a Host Name, Type (DHCP or Fixed), IP Address, Subnet Mask, and Gateway
IP Address.
Note: For NetLinx Central Controllers, the "Host Name" can only consist of
alphanumeric characters.
Enter Y (yes) to approve/store the information into the Master.
Enter N (no) to cancel the operation.
Note: The Device must be rebooted to enable new settings.
Example:
>SET IP [0:1:0]
--- Enter New Values or just hit Enter to keep current settings ---
Enter Host Name: MLK-INSTRUCTOR
Enter IP type. Type D for DHCP or S for Static IP and then Enter:
DHCP
Enter Gateway IP: 192.168.21.2
You have entered: Host Name MLK-INSTRUCTOR
Type DHCP
Gateway IP 192.168.21.2
Is this correct? Type Y or N and Enter -> y
Settings written. Device must be rebooted to enable new settings.