Specifications
Terminal (Program Port/Telnet) Commands
99
NetLinx Integrated Controllers- WebConsole & Programming Guide (FMv3) 
Terminal Commands (Cont.)
Command Description
IP STATUS  Provides information about the current NetLinx IP Connections.
Example:
>IP STATUS
 NetLinx IP Connections
 No active IP connections
IPSEC ON|OFF|STATUS Enables/Disables IPSec security or displays current setting.
MEM Displays the largest free block of the Master’s memory.
Example:
>MEM
The largest free block of memory is 11442776 bytes.
MSG ON|OFF Enables/Disables extended diagnostic messages.
• MSG On [error|warning|info|debug] sets the terminal program to display 
log messages generated by the Master.
The level of log printed to the terminal window depends both on the level 
used when sending the message and the output level selected with 
"msg on." 
For example if log output is enabled via "msg on warning" then logs 
produced at levels AMX_ERROR and AMX_WARNING will be 
displayed, but not logs produced at levels AMX_INFO or AMX_DEBUG. 
The order of severity from highest to lowest is ERROR, WARNING, 
INFO, DEBUG. 
If no severity is supplied with "msg on", the default setting is WARNING.
• MSG OFF disables the display.
Example:
> MSG ON
 Extended diagnostic information messages turned on.
> MSG OFF
 Extended diagnostic information messages turned off.
MSG STATS Calculates incoming and outgoing messages over a time interval.
OFF [D:P:S or NAME,CHAN] Turns off a specified channel on a device. The device can be on any sys-
tem that the Master you are connected to is able to reach. 
You can specify the device number, port, and system, or the name of the 
device that is defined in the DEFINE_DEVICE section of the program.
Syntax:
OFF[name,channel]
-or-
OFF[D:P:S,channel]
Example:
>OFF[5001:7:4]
 Sending Off[5001:7:4]
ON [D:P:S or NAME,CHAN] Turns on a specified channel on a device. The device can be on any 
system that the Master you are connected to is able to reach. 
You can specify the device number, port, and system, or the name of the 
device that is defined in the DEFINE_DEVICE section of the program.
Syntax:
ON[name,channel]
-or-
ON[D:P:S,channel]
Example:
>ON[5001:7:4]
 Sending On[5001:7:4]