Specifications

Introduction
2
NetLinx Integrated Controllers
Pages section on page 116 for more detailed information on the use of Dynamic Device Discovery
(DDD).
These NI Controllers use a combination lithium battery and clock crystal package called a
Timekeeper. Only one Timekeeper unit is installed within a given NI controller. The battery can be
expected to have up to 3 years of usable life under very adverse conditions. Actual life is
appreciably longer under normal operating conditions. This calculation is based on storing the unit
without power in 50° C (120° F) temperature until battery levels are no longer acceptable. The part
number for a replacement battery is 57-0032.
NI-2100 Specifications
The NI-2100 (FIG. 1) provides support for 3 RS-232/RS-422/RS-485 Ports, 4 IR/Serial Output
ports, 4 Digital Input/Output ports, and 4 Relays. The NI-2100 can be upgraded to provide
1 ICSHub and 2 ICSNet ports by either installing the optional ICSNet daughter card (FG2105-10)
or purchasing this upgrade as an included feature of the NI-2100 Kit (FG2105-14).
FIG. 1 NI-2100 NetLinx Integrated Controller (front view)
FIG. 2 NI-2100 front and rear panel connectors and components
PORT 3 PORT 2
5
GND
PORT 1
TXD
RXD
RS - 232 / 422 / 485
Function
4
TX+
3
2
RX-
1
Pin
9
7
8
6
Pin
(Ports 1-3)
TX-
RTS
CTS
RX+
Function
L/A
10 / 100
ETHERNET
SPD
OUTPUT
INPUT
STATUS
LINK/ACT
TX RX
2
RS - 232 / 422 / 485
RX
1
TX TXRX
3
2
RELAYS
143
IR / SERIAL
1234 231
I / O
4
AXlink LED
Relays
RS-232/422/485 (Ports 1-3)
I/O (Port 9)
IR/Serial (Ports 5-8)
Front
Rear
Program
DIP
switch
ICSNet cover plate
(green)
ID Pushbutton
(Port 4)
Ethernet
AXlink
port
PWR
RS-232/422/485 TX/RX LEDs (red/yellow)
Relay LEDs (red)
IR/Serial LEDs (red)
I/O LEDs
port
Link/Active-Status-Output-Input
(yellow)