Specifications

Installation
17
MXD/T-700 7" Modero® X Series Touch Panels
3. After ensuring proper placement, cut out the mounting surface for the back box, using the MXD-700
Installation Template as a guide.
4. Thread the incoming Ethernet from their terminal locations through the surface opening (FIG. 17). Leave
enough slack in the wiring to accommodate any re-positioning of the panel.
FIG. 16 MXD-700 Installation Template
7 5/16"
6 9/16"
4 1/16"
4 13/16"
(10.32 cm)
(12.22 cm)
(18.50 cm)
(16.67 cm)
Using the included template to select the final placement of the back box is highly
recommended. The outside edges of the template are the same dimensions as the
touch panel, which allows you to troubleshoot possible conflicts with wall edges,
doors, and other potential obstacles.
Making sure the actual cutout opening is slightly smaller than the provided
dimensions is highly recommended. This action provides the installer with a margin
for error if the opening needs to be expanded. Too little wall material removed is
always better than too much.