Configuring Communication
40
MVP-9000i Modero® Wireless Touch Panel with Intercom
Using G4 Web Control to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4-enabled panel via the Web. This
feature works in tandem with the browser-capable NetLinx Security firmware update (build 300 or higher).
G4 Web Control is only available with the latest Modero panel firmware.
Refer to the G4 Web Control Settings Page section on page 88 for more detailed field information.
1. From the Setup page, press the Protected button (located on the lower-left of the panel page) to open the
Protected Setup page and display an on-screen keypad.
2. Press the G4 WebControl button to open the G4 Web Control Settings page (FIG. 41).
3. Press the G4 Web Control button until it toggles to On and turns green.
4. The Control Name field is exactly the same as the Device Name field in the Protected Setup page.
5. Press the Control Password field to open the Web Password keyboard.
6. From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4
Authentication session password associated with VNC web access of this panel.
7. Press OK to save all changes and return to the G4 Web Control Settings page or Abort to return to the
page without saving any changes.
8. Press the Control Port field to open the Web Port Number keypad.
9. Within the keypad, enter a unique numeric value to be assigned to the port on which the VNC Web Server
is running. The default value is 5900. Press OK after entering the value.
10. Press the Up/Down arrows in the Timeout section to increase or decrease the amount of time the device
can remain idle with no cursor movements before the session is closed and the user is disconnected. The
options are Off; 3, 5, 10, 15, and 30 minutes; and 1, 2, 3, and 4 hours.
11. Press the Back button twice to return to the Status page and save any changes.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from www.amx.com. Refer to the NetLinx Master instruction
manual for more detailed information on the use of the new Web-based NetLinx
Security.
FIG. 41 G4 Web Control Settings page
Verify that the NetLinx Master’s IP Address and System Number have been properly
entered into the Master tab of the System Settings page.