Specifications

Protected Setup Pages
80
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom, 5.2 and 5”
To change a previously established password:
1. In the Password Settings page, press the button in the In Panel Password Change section for the particular
password to be changed.
2. In the Pass word keyboard, enter the new alphanumeric password.
3. Press Done when complete.
To list a new user within the User Access section:
1. Press a blank button in the User Access section.
2. In the Name keyboard, enter the user’s name or nickname and press Done when finished.
3. In the Pass word keyboard, enter the selected alphanumeric password and press Done when finished.
4. The new users name will appear in the left column of User Access section. The password will also appear
in the right column, but its characters will be replaced with asterisks.
To change a User Access password:
1. Press the button corresponding to the user’s name in the User Access section.
2. In the Pass word keyboard, enter the user’s password and press Done.
3. Press the password button in the right column of the User Access section.
4. Enter the new password into the Password keyboard and press Done.
To view all previous instances of users accessing the device:
1. From the Password Settings page, press the Enable button to highlight it. The MVP-5200i will record all
successful and unsuccessful attempts to access the touch panel.
2. Press the Record button to send a record to the network Master of all recorded attempts to access the
device. This record may be retrieved from the Master at any time.
Password Settings Page (Cont.)
Enable/Enabled: The Enable/Enabled button allows you to toggle between activating or
deactivating the MVP panel requirement of a user to enter a pre-defined
password before removing the panel from a connected docking station:
Enable - does not prompt the user for a password, the docking station just
releases the panel when the security release pushbutton is pressed.
Enabled - requires that a valid password from the User Access list be entered
before removing a panel from a docking station.
Report: The Report button enables/disables reporting the panel’s docking status to the
Master.
Password 5 is protected, and can only be changed by the Administrator.
Only one of the main passwords may be used to access the Protected Settings page.
An individual user password may not be used to access the Protected Settings page
unless it matches one of the main passwords.
No matter how many characters are in an actual password, the Password column in
the User Access section will always show five asterisks.
For more information on removing an MVP-5200i from a MVP-WCS-52 Charging
Station, please refer to the Unlocking the Touch Panel section on page 12.