Specifications
Configuring Communication
37
MVP-5200i Modero® ViewPoint® Touch Panel with Intercom, 5.2 and 5”
5. Press the Enable/Enabled button until it toggles to Enabled and turns light blue.
6. The Network Interface Select field is read-only and displays the method of communication to the web.
Wireless is used when a wireless card is detected within the internal card slot. This method
provides an indirect communication to the web via a pre-configured Access Point.
7. Press the Web Control Name field to open the Web N a m e keyboard.
8. From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel.
This information is used by the NetLinx Security Web Server to display on-screen links to the
panel.
The on-screen links use the IP Address of the panel and not the name for communication (FIG. 41).
9. Assign the alpha-numeric string for the Web Control name and then press Done.
10. Press the Web Control Password field to open the Web Pa s s w ord keyboard.
11. From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4
Authentication session password associated with VNC web access of this panel.
12. Press Done after assigning the alpha-numeric string for the Web Control password.
13. Press the Web Control Port field to open the Web Po r t Numbe r keypad.
14. Within the keypad, enter a unique numeric value to be assigned to the port on which the VNC Web Server
is running. The default value is 5900. Press Done after entering the value. The remaining fields within the
G4 Web Control Settings section of this page are read-only and cannot be altered.
15. Press the Up/Down arrows on either sides of the G4 Web Control Timeout field to increase or decrease the
amount of time the device can remain idle with no cursor movements before the session is closed and the
user is disconnected.
16. Press the Back button to open the Protected Setup page.
17. Press the on-screen Reboot button to save any changes and restart the device.
The Network Interface Select field is read-only and defaulted to Wireless, since the
device has no Ethernet cable connection.
FIG. 41 Sample relationship between G4 Web Control and Mange WebControl Connections window
Verify that the NetLinx Master’s IP Address and System Number have been properly
entered into the Master Connection section of the System Settings page.