Standby Mode
Standby Mode can be activated via channel 100 on the DVX. The following points apply to Standby Mode on the DVX:
After exiting Standby Mode, the DVX cannot re-enter Standby Mode for a period of 20 seconds. Any attempt
to re-enter standby mode within this 20 second window is ignored.
When the DVX enters Standby Mode, all video and audio circuitry are turned off. The DVX does not produce
a video or audio output signal in low power state.
The 5002 Device stays online when Standby Mode is active.
All switch and configuration commands sent while in Standby Mode are implemented, and any changes will
be noticed after the DVX exits Standby Mode.
All audio and video signals are restored in less than 10 seconds after exiting Standby Mode.
The DVX exits Standby Mode on any power cycle or reboot.
NetLinx Channels (Cont.)
Channel Ports Description
152 1-6 Video In Contrast Ramp Up (only applicable when routed to a
scaled output)
153 1-6 Video In Contrast Ramp Down (only applicable when routed to a
scaled output)
156 1-6 Video In Hue Ramp Up (only applicable when routed to a scaled
output)
157 1-6 Video In Hue Ramp Down (only applicable when routed to a
scaled output)
158 1-2 Output Zoom Ramp Up
159 1-2 Output Zoom Ramp Down
164 1-3 Audio Output Balance Ramp Left (output 1 is only applicable on
-SP units)
165 1-3 Audio Output Balance Ramp Right (output 1 is only applicable on
-SP units)
196 1-3 Source Cycle
199 1-3 Volume Mute Set and State
210 1-3 Video Mute Set and State
213 1-2 Video Freeze Set and State
216 1 Fan Alarm (read-only channel)
217 1 Temperature Alarm (read-only channel)
234 1-2 OSD State