Enova DVX-2150HD/2155HD All-in-One Presentation Switcher Operation/Reference Guide
Standby Mode
Standby Mode can be activated via channel 100 on the DVX. The following points apply to Standby Mode on the DVX:
After exiting Standby Mode, the DVX cannot re-enter Standby Mode for a period of 20 seconds. Any attempt
to re-enter standby mode within this 20 second window is ignored.
When the DVX enters Standby Mode, all video and audio circuitry are turned off. The DVX does not produce
a video or audio output signal in low power state.
The 5002 Device stays online when Standby Mode is active.
All switch and configuration commands sent while in Standby Mode are implemented, and any changes will
be noticed after the DVX exits Standby Mode.
All audio and video signals are restored in less than 10 seconds after exiting Standby Mode.
The DVX exits Standby Mode on any power cycle or reboot.
NetLinx Channels (Cont.)
Channel Ports Description
152 1-6 Video In Contrast Ramp Up (only applicable when routed to a
scaled output)
153 1-6 Video In Contrast Ramp Down (only applicable when routed to a
scaled output)
156 1-6 Video In Hue Ramp Up (only applicable when routed to a scaled
output)
157 1-6 Video In Hue Ramp Down (only applicable when routed to a
scaled output)
158 1-2 Output Zoom Ramp Up
159 1-2 Output Zoom Ramp Down
164 1-3 Audio Output Balance Ramp Left (output 1 is only applicable on
-SP units)
165 1-3 Audio Output Balance Ramp Right (output 1 is only applicable on
-SP units)
196 1-3 Source Cycle
199 1-3 Volume Mute Set and State
210 1-3 Video Mute Set and State
213 1-2 Video Freeze Set and State
216 1 Fan Alarm (read-only channel)
217 1 Temperature Alarm (read-only channel)
234 1-2 OSD State